42
SV200 DC Hardware Manual
920-0126A
4/14/2017
High-Speed
Pulse Inputs
PULSH1
44
H
igh-speed pulse inputs (+5VDC line drive input), the maximum input frequency 2MHz.Three
pulse commands available:
●
Pulse & Direction
●
CW Pulse and CCW Pulse
●
A Quadrature B pulse
(NOTE: DO NOT use with both X1 and X2)
PULSH2
45
SIGNH1
46
SIGNH2
47
Analog Input
Signal 1
ANA1
16
In analog velocity control mode, the offset, dead band, and function of analog input 1 can be set by
SVX Servo Suite or parameters P-52, P-56 and P-61.
●
Sets or requests the analog input gain that relates to motor position when the drive is in
analog position command mode
●
Sets or requests the gain value used in analog velocity mode
●
General analog input in Q mode
DGND
15
Digital Ground for analog input
Analog Input
Signal 2
ANA2
18
●
In analog torque control mode, the offset, dead band, and function of analog input 2 can be
set by SVX Servo Suite or parameters P-53, P-57 and P-61.
●
General analog input in Q mode
DGND
17
Digital ground for analog input
4.8.2.3 Input Function List
1
2
3
4
5
6
7
8
9
10
11
12
Step
■
DIR
■
CW Limit
●
CCW Limit
●
Start/Stop
▲▼
Direction
▲▼
Servo enable
●
Alarm clear
●
Speed selection 1,2,3
▲
▲
▲
Global gain selection
■
Control mode selection
●
Pulse encoder Resolution
selection
■
Pulse Inhabit
■
General Input
●
●
●
●
●
●
●
●
●
●
●
●
■
■
– Position Mode ■
▲
– Velocity Mode ■
▼
– Torque Mode ■
●
– All Modes