157
SV200 DC Hardware Manual
920-0126A
4/14/2017
9.3.9 Modbus/RTU Applications
9.3.9.1 Position Control
Target Profile Planning
SCL
command
Target
Value
Unit
Dec
Dec (Hex)
Description
AC
100
rps/s
40028
600 (258h)
The unit for register 40028 is
rps
2
, when target
acceleration is 100rps/s, the value will be 600
DE
200
rps/s
40029
1200 (4B0h)
The unit for register 40029 is
rps
2
. When target
deceleration is 200 rps/s, the value will be 1200
VE
10
rps
40030
2400 (960h)
The unit for register 40030 is
. When target velocity
is
10 rps/s, the value will be 2400
DI
20000
counts
40031~40032 20000 (4E20h) The target distance will be 20000 counts
Drive Setting
Parameter
Function
P-75 (PR) = 5
Big-endian data transfer
P-76 (TD) = 10
feedback delay 10ms
P-77 (BR) = 3
communication baud rate 38400bps
P-78 (DA) = 1
Communication address 1
P-14 (PM) = 8
Power up mode as Modbus/RTU