Software Configuration
On the Motor Configuration page - Control Mode Settings select pulse input type and input filter type.
7.2.3 Input Pulse Dividing Ratio Setting and Dividing Switch
Input X9 is used as the control pulse dividing switch function. When this function is on, it will allow the drive to change the number to
encoder counts per motor revolution
A. The pulse dividing ratio setting
The pulse dividing ratio sets the number of pulse input count per motor revolution.
The first pulse dividing ratio is set via parameter P-39 (EG), the second pulse dividing ratio is set via P-40 (PV).
Note: if you using drive’s control panel for configuration, please refer to the follow :
Drive Display value =
EG
x
2
Where
EG
is the target pluse count per rev, unit counts
Software Configuration
B. Diviing Switch Setting
In factory default mode, pulse dividing switch is disabled. It can be set by SVX Servo Suite or parameter P-65 (MI) directly from the
drive’s control panel. The second digit of P-65 (MI) (right to left) is used to set switching conditions.
Signal
Name
PIN
P-65 (MI)
Condition
Function
X9
X9 (26)
□□1□
Closed
Use 1st pulse dividing ratio ------ P-39 (EG)
Open
Use 2nd pulse dividing ratio ------ P-40 (PV)
□□2□
Closed
Use 2nd pulse dividing ratio ------ P-40 (PV)
Open
Use 1st pulse dividing ratio ------ P-39 (EG)
□□3□
(default)
Always use 1st pulse dividing ratio ----P-39 (EG)
NOTE: ONLY set the pulse dividing ratio function, when no pulse command is being sent
into the drive, i.e. the motor is NOT moving.
Software Configuration
On the Drive Configuration page - Input & Output select X9 input to set up.