92
SV200 DC Hardware Manual
920-0126A
4/14/2017
7.3.3.2 Analog Velocity Gain
Analog input voltage range is between -10V~+10V. In analog velocity, setting the velocity value and correspondent input voltage value
is required. This can be set via SVX Servo Suite software or P-50 (AG) on the drive’s control panel.
Parameter
Name
Data Range
Default
Unit
LED
Display
Description
P-50 (AG)
Analog Velocity
Gain
-100~100
20
rps
4800
The corresponding motor rotary velocity for
10vdc analog input voltage.
NOTE: When viewing or setting the velocity value on the drive’s control panel, please refer to the
following calculation:
Drive display value= x 240
is target setting velocity rev/second (rps)
Setting Via Software
7.3.3.3 Analog Input Voltage Offset
In some cases, even when the host controller sets the analog command to 0V, the servo motor might still rotate slowly. This is caused
by a voltage bias from the analog voltage supply. SVX Servo Suite can automatically offset the analog voltage bias, or users can
manually adjust the tuning voltage offset value by changing parameters P-52 (AV1) and P-53 (AV2).
Parameter
Name
Data Range
Default
Unit
LED
Display
Description
P-52 (AV1)
Analog input 1 offset
-10 - 10
0
V
0
Set Analog input 1 offset
P-53(AV2)
Analog input 2 offset
-10 - 10
0
V
0
Set Analog input 2 offset
P-54(AV3)
Differential Analog offset
-10 - 10
0
V
0
Set differential analog input offset
NOTE: When viewing or setting this value on the drive’s control panel, refer to following calculation:
Drive display value= x 2730
is target setting offset, unit Voltage (V)
Setting Via Software