160
SV200 DC Hardware Manual
920-0126A
4/14/2017
9.3.9.2 JOG mode
JOG mode required parameters:
SCL
command
Target
Value
Unit
Dec
Dec (Hex)
Description
AC
100
rps/s
40047
600 (258h)
The unit for register 40028 is
rps
2
, when target
acceleration is 100rps/s, the value will be 600
JL
200
rps/s
40048
1200 (258h)
The unit for register 40029 is
rps
2
. When target
deceleration is 200rps/s, the value will be 1200
JS
10
rps
40049
2400 (960)
The unit for register 40030 is
. When target velocity
is
200rps/s, the value will be 1200
Drive Setting
Parameter
Function
P-75 (PR) = 5
Big-endian data transfer
P-76 (TD) = 10
Feedback delay 10ms
P-77 (BR) = 3
Communication baud rate 38400bps
P-78 (DA) = 1
Communication address 1
P-14 (PM) = 8
Power up mode as modbus/rtu
Use SVX Servo Suite software for configuration: