94
SV200 DC Hardware Manual
920-0126A
4/14/2017
7.3.3.6 Torque Limit
In single-ended analog mode, analog input 2 (ANA2) can used to set motor’s output torque.
Parameter Settings
Parameter
Name
Data Range
Default
value
Unit
LED
Display
Description
P-55 (AS)
Analog type
0~1
0
1
Analog input type
0: Single ended input 1: Differential input
P-62 (FA2)
Analog 2 function
setting
2~3
3
3
□
Analog input port 2 function setting
2: Torque limit setting 3: Not in use
P-51 (AN)
Analog Torque
Gain
Based on
drive’s
output
ability
1
A
100
Sets correspondening torque output value
against 10VDC input voltage.
NOTE: When viewing or setting this value on the drive’s control panel (P-51 (AN)), refer to the following calculation:
Drive display value= x 100
where is target torque output value
Setting Via Software
7.3.3.7 Target Velocity Reached
In velocity mode, when the motor’s actual velocity and commanded target velocity are the same, the “velocity reached” output signal
can be sent by output Y4 .
The second digit (from right to left) of parameter P-68 (MO) defines the output signal Y4.
Signal Name
PIN
P-68 (MO)
Condition
Function
Y4
Y4 (43)
OUT- (33)
□□B□
Closed
Closed means target speed not reached
Open
Open means reach output speed
□□A□
Closed
Close means reach output speed
Open
Open means target speed not reached
□□3□
(default)
General purpose signal, function disabled.