132
SV200 DC Hardware Manual
920-0126A
4/14/2017
P-66 (AO)
Alarm output function setting
Data Range
Default
Unit
LED Display
1~3
3
---
1
Defines usage of digital output Y1. Normally this output is used to indicate an Alarm caused by a Drive Fault. This output can being
reconfigured as a general purpose output for use with other types of output commands. There are three states that can be defined:
AO1: Output Y1 is closed (active, low) when a Drive Fault is present. AO2: Output Y1 is open (inactive, high) when an Drive Fault is
present. AO3: Output Y1 is not used as an Alarm Output and can be used as a general purpose output.
P-67 (BO)
Motor brake control setting
Data Range
Default
Unit
LED Display
1 - 3
1
---
1
BO defines the usage of digital output Y2 as the Brake Output, which can be used to automatically activate and deactivate a holding
brake. Output Y2 can also be configured as a general purpose output for use with other types of output commands. There are three
states that can be defined:
BO1: Output Y2 is closed (energized) when the drive is enabled, and open when the drive is disabled.
BO2: Output Y2 is open (de-energized) when the drive is enabled, and closed when the drive is disabled.
BO3: Output Y2 is not used as a Brake Output and can be used as a general purpose output.
Refer to Section 7.1.7 Motor Brake Control.