128
SV200 DC Hardware Manual
920-0126A
4/14/2017
P-51 (AN)
Analog Torque Gain
Data Range
Default
Unit
LED Display
Drive’s maximum current
output ability
0.5
A
50
This parameter sets the analog input gain that relates to motor torque when the drive is in analog torque control mode. Analog torque
gain value sets the commanded torque when the analog input is at the configured full scale value (±10V).
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
A
x 100
Where
A
is target toruqe setting, Unit is A (Amp)
P-52 (AV)
Analog input1 offset
Data Range
Default
Unit
LED Display
-10.000 - +10.000
0.000
V
0
The offset value of analog input 1 in volts. In some cases, even when host controls set the analog command to 0V, the servo motor
might still rotate slowly. This is caused by voltage bias from the analog voltage supply. This can be adjusted by this offset value.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 2730
Where is voltage offset, Unit is V.
P-53 (AV)
Analog input 2 offset
Data Range
Default
Unit
LED Display
-10.000 - +10.000
0.000
V
0
The offset value of analog input 2 in volts. Refer to Section 7.4.3.3 Analog Input Voltage Offset.
P-54 (AV)
Differential analog input offset
Data Range
Default
Unit
LED Display
-10.000 - +10.000
0.000
V
0
The offset value of differential analog input in volts. Refer to Section 7.4.3.3 Analog Input Voltage Offset.
P-55 (AS)
Analog type
Data Range
Default
Unit
LED Display
0 - 1
0
-----
0
This is the analog input scaling setting that determines what type of analog input scaling is desired.
0: single ended input
1: differential input
P-56 (AD)
Analog input 1 deadband
Data Range
Default
Unit
LED Display
0 - 255
0
mV
0
The analog deadband value of analog input 1 in millivolts. The deadband value is the zone around the “zeroed” value of the analog
input. This deadband defines the area of the analog input range that the drive should interpret as “zero”. The deadband is an absolute