133
SV200 DC Hardware Manual
920-0126A
4/14/2017
P-68 (MO)
Y3, Y4, Y5, Y6 output function
setting
Data Range
Default
Unit
LED Display
413D
---
413D
P-68 (MO) defines Y3, Y4, Y5, and Y6 output functions, by 4 digits from right to left.
Digit 4: Y6 Function
Digit 1: Y3 Function
Digit 2: Y4 Function
Digit 3: Y5 Function
Digit 1 defines output Y3
8: When the output torque reaches the targeted torque, output Y3 is closed
9: When the output torque reaches the targeted torque, output Y3 is open
D: When the drive is in servo ready status, output Y3 is closed.
E: When the drive is in servo ready status, output Y3 is open.
3: Output Y3 is used as a general purpose output.
Digit 2 defines output Y4
6: When the dynamic position error is within the range specified by the PL command, output Y3 is closed.
7: When the dynamic position error is within the range specified by the PL command, output Y3 is open.
A: When the actual velocity reaches the targeted velocity, output Y3 is closed.
B: When the actual velocity reaches the targeted velocity, output Y3 is open.
3: Output Y4 is used as a general purpose output.
Digit 3 defines output Y5
1: When the drive is enabled, output Y5 is closed.
2: When the drive is enabled, output Y5 is open.
3: Output Y5 is used as a general purpose output.
Digit 4 defines output Y6
4: When the motion is completed and the motor is in position, output Y3 is closed.
5: When the motion is completed and the motor is in position, output Y3 is open.
C:When the motor is running, Y6 is set for tach output.
3: Output Y6 is used as a general purpose output.
In SVX Servo Suite Parameter Table tab, 4 commands are listed: MO1 represents digit 1 (Y3), MO2 represents digit 2 (Y4), MO3
represents digit 3 (Y5), MO4 represents digit 4 (Y6).