10
www.analogway.com
PROGRAMMER’S GUIDE
PROGRAMMER’S GUIDE
PROGRAMMER’S GUIDE
PROGRAMMER’S GUIDE
PROGRAMMER’S GUIDE
PROGRAMMER’S GUIDE
PROGRAMMER’S GUIDE
PROGRAMMER’S GUIDE
USER MANUAL
1.9
Technical specifications
Dimensions
(in Rack Units - RU)
•
2RU
Dimensions
(without rack ears and rear rack mount)
•
W 17.28’’ x H 3.46’’ x D 14.82’’
•
L 439 mm x H 88 mm x P 381 mm
Dimensions
(with handles)
•
W 19’’ x H 3.46’’ x D 15.81’’
•
L 482.1 mm x H 88 mm x P 406 mm
Weight without accessories
•
6.2 kg / 13.66 lbs.
Shipping weight accessories included
•
8.7 kg / 19.18 lbs.
Noise
(@1,6m height @25°C)
•
Front: 39 DBa@1m
•
Rear: 39 DBa@1m
Thermal dissipation
•
154 BTU/hr.
Operating altitude
•
3000 m / 9842 ft.
Warranty
•
3-year warranty on parts and labor back to
factory
Power Supply
•
100-240 VAC 50/60Hz 3.2A
•
Fuse cartridge F4AH 250VAC 5x20mm
•
Max consumption: 45 W@100VAC without
any option card
Supplied with
•
1 x Power supply cord
•
1 x Pair of front h screws
•
1 x Rackmount kit
•
1 x Ethernet cross cable (for device control)
•
1 x MCO 5 pin connector
•
1 x Quick Start Guide including safety
instructions*
(*) All technical specifications and videos are available on
analogway.com
NOTE:
Specifications subject to change without prior notice.
1.10
Environmental specification
General:
•
Cooling air flows from front to rear
•
Storage temperature: -25°C to +70°C (-13°F
to +158°F)
•
Operating temperature: 0°C to +40°C (+32°F
to +104°F)
•
Storage humidity: 10% to 80% non-
condensing
•
Operating humidity: 10% to 80% non-
condensing
•
Operating altitude: max 3000m / 9842ft
Environment:
•
RoHS 2: EN50581 (2012)
Electrical security:
•
IEC 60950-1:2005 (ED.2); A1:2009; A2:2013
•
EN 60950-1:2006 + A1:2010 + A11:2009 +
A12:2011 + A2:2013
•
UL 60950-1, 2nd Edition 2014
•
CSA C22.2#60950-1 (2007/03/27), A1:2011;
A2:2014
•
ETL LISTED (CANADA & US)
Electromagnetic compatibility:
•
IEC 61000-3-2 (2014)
•
IEC 61000-3-3 (2013)
•
EN55022 (2010)
•
EN55022 (2010)
•
EN55024 (2010)
•
FCC Part15 of 2012
•
IECS-003 of August 2012