44
www.analogway.com
PROGRAMMER’S GUIDE
PROGRAMMER’S GUIDE
PROGRAMMER’S GUIDE
PROGRAMMER’S GUIDE
PROGRAMMER’S GUIDE
PROGRAMMER’S GUIDE
PROGRAMMER’S GUIDE
PROGRAMMER’S GUIDE
USER MANUAL
Web RCS
1.
Go to the
Setup
menu on the Web RCS interface.
2.
Click on the
CONTROL
tab to access the device settings and control functions.
3.
In the left side toolbar, select
GPO
to access the GPOs settings page.
4.
Under
GPO 1
(or
GPO 2
), choose the mode for GPO 1 (or 2).
List of possible GPO modes:
(*) Requires input selection (see below)
5.
If required, specify the
input
used for the GPO 1 (or 2) mode (/!\ available for automatic with input-
dependency modes only).
If you are using the
VIO 4K
for the first time, you can reset the device to factory settings (as-is out of the box)
to start enjoying the unit as a brand new device.
You can also simply reset the unit to its configuration default values to keep the
Frame Library
and the
current configuration of your
Network
,
Web RCS
and
Link
settings.
FORCE OPEN STATE
Open by user action
FORCE CLOSED STATE
Closed by user action
CLOSED IF INPUT IS DISPLAYED
Closed when the user-specified input is displayed (*)
CLOSED IF NO INPUT IS DISPLAYED
Closed when no input is displayed
CLOSED IF INPUT SIGNAL IS VALID
Closed when the user-specified input is valid (*)
OPEN IF INPUT IS DISPLAYED
Open when the user-specified input is displayed
OPEN IF NO INPUT IS DISPLAYED
Open when no input is displayed
OPEN IF INPUT SIGNAL IS VALID
Open when the user-specified input is valid (*)
5.7
Resetting the unit