3.2.6. Menu differences in other operating modes.
3.2.6.1. All modes except Xpeak.
Xpeak mode is the only one that supports families characterized by a defined color of the LED
associated to each cross-point key. Thus, these LEDs don’t illuminate in the rest of operating
modes.
3.2.6.2. Conexia and CrossNET modes.
In these modes, operation using a matrix means that specific options are defined in the
CrossMapper
software for general system configuration.
When in these operating modes, the first menu shows two specific functions:
•
"
Reject
"
:
It allows to cut off a communication. If a remote panel has
established communication with our panel and we want to "hang up"
that "call" this option should be used. When selecting it by pressing the
"
PAGE
(MUTE)" key, the display returns to the operation screen,
where the key whose communication you want to cut off is selected.
Then the key will be disabled both in the source panel of the
communication and in the destination panel.
•
"
Mute Key
"
:
The functionality is the same as defined in section 3.2.1.1.
3.2.6.3. EasyNET and EasyNET G722 modes.
They are 4-channel Party-Line modes, so in operating mode there are only 4 active keys.