Power meter Specific Functions
•
the <top> key moves the display window to the first set of memorised results
in the table
•
the <Middle> moves the display window to the middle of the memorised
results in the table
•
the <Bottom> moves the display window to the end of the memorised results
in the table
•
the < Current Line> moves the cursor to the last memorised result.
Editing the fiber number
The <Edit Fiber Nb> key enables the modification of the fiber number for the
selected result.
If this number is modified in the Memory menu, then it is automatically updated
in the Configuration menu accessed by the
File
button. Conversely, if a new fiber
number is entered in the File menu, it will be used when the results are next
stored in the memory.
Incrementing the fiber number
The <Incremen Fiber Nb> key increases the number at the next save. This
number is also incremented in the Configuration menu accessed by the File
button.
Saving the current measurement result
To save the currently displayed measurement result (or, if the TwinTest mode is
detected, the two corresponding results):
1.
From the OTS Results window press the <Memories> key, then the
<Display> key.
2.
Use the <Top>, <Middle>, <Bottom>or <Current Line> key in conjunction
with the
↓
and
↑
directional arrows to select the memory location to store the
result.
3.
Press the <Save Result> key.
The current measurement is saved in the selected line of the memory (and in the
following lines in the TwinTest mode).
Automatic result storage
The power meter can automatically save up to 300 results at predefined intervals
while Run is executed with the
STOP/START
direct access key. When this key is
pressed to stop the execution the File window is automatically displayed to save
the results in a file.
Use the following procedure to automatically store results:
1.
Press the
SET-UP
direct access key to display the
OTS TEST SETUP
window.
2.
In the
Powermeter
menu select:
mode
/
Autostore
.
3.
Select the time interval with the
Time Auto
menu option, 1 second to 11 hours
59 minutes and 59 seconds in 1 second increments.
4.
Press the
RESULTS
direct access key then the <Memories> softkey to display
the memories.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com