Description
Setting for
ACS880 drives
Drive parameter
Acceleration time 1
53.03 FBA data out3
Deceleration time 1
23.13
53.05 FBA data out5
Validates the configuration parameter set-
tings.
1 =
Selects speed control as the control mode 1
for external control location EXT1.
2 =
Selects fieldbus adapter A as the source of
the start and stop commands for external
control location EXT1.
12 =
Selects a level-triggered start signal for ex-
ternal control location EXT1.
1 =
Selects fieldbus A reference 1 as the source
for speed reference 1.
4 = FB A ref1
1) Read-only or automatically detected/set
2) Example
The start sequence for the parameter example above is given below.
Control word
•
after power-on, fault or emergency stop:
•
476h (1142 decimal) –> NOT READY TO SWITCH ON
•
in normal operation:
•
477h (1143 decimal) –> READY TO SWITCH ON (stopped)
•
47Fh (1151 decimal) –> OPERATING (running)
Fieldbus control through a fieldbus adapter 741
Содержание ACS880 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 ESP control program option N5600 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 16: ...16 ...
Страница 22: ...22 ...
Страница 24: ...24 ...
Страница 44: ...44 ...
Страница 66: ...66 ...
Страница 148: ...148 ...
Страница 167: ...Fieldbus control macro This application macro is not supported by the current firmware version Application macros 167 ...
Страница 168: ...168 ...
Страница 704: ...704 ...
Страница 728: ...728 ...
Страница 742: ...742 ...
Страница 762: ...762 ...