Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
0
Type/source and scaling follow the type of reference
1 selected by parameter
. See the individual settings below for the sources
and scalings.
Auto
1
Reserved.
2
Reserved.
3
is sent as actual value 1. The scaling
is defined by parameter
.
Torque
4
is sent as actual value 1. The
scaling is defined by parameter
.
Speed
5
is sent as actual value 1. The
scaling is defined by parameter
Frequency
Auto / uint16
Selects the type/source and scaling of actual value
ACT2 transmitted to the external controller.
DDCS controller act2
type
60.63
0
Type/source and scaling follow the type of reference
2 selected by parameter
. See the individual settings below for the sources
and scalings.
Auto
1
Reserved.
Auto
2
Reserved.
Auto
3
is sent as actual value 2. The scaling
is defined by parameter
.
Torque
4
is sent as actual value 2. The
scaling is defined by parameter
.
Speed
5
is sent as actual value 2. The
scaling is defined by parameter
Frequency
0 / uint16
Selects the pair of data sets used by the mailbox service
in the drive/controller communication.
See section
External controller interface (page 81)
Mailbox dataset
selection
60.64
- / -
Data sets 32 and 33.
0...1
- / uint16
Activates DDCS controller communication monitoring
separately for each control location (see section
control vs. external control (page 39)
The parameter is primarily intended for monitoring the
communication with the controller when it is connected
to the application program and not selected as a
control source by drive parameters.
DDCS controller
comm supervision
force
60.65
1 = Communication monitoring active when Ext 1 is
being used.
Ext 1
b0
1 = Communication monitoring active when Ext 2 is
being used.
Ext 2
b1
1 = Communication monitoring active when local
control is being used.
Local
b2
Reserved
b3…15
1 = 1
0000h…FFFFh
504 Parameters
Содержание ACS880 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 ESP control program option N5600 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 16: ...16 ...
Страница 22: ...22 ...
Страница 24: ...24 ...
Страница 44: ...44 ...
Страница 66: ...66 ...
Страница 148: ...148 ...
Страница 167: ...Fieldbus control macro This application macro is not supported by the current firmware version Application macros 167 ...
Страница 168: ...168 ...
Страница 704: ...704 ...
Страница 728: ...728 ...
Страница 742: ...742 ...
Страница 762: ...762 ...