Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
180 deg / real32
Defines a phase shift for the output of the filter.
Note: Before changing this parameter run-time, disable
the oscillation damping output using parameter
.
Monitor the behavior of
before re-enabling the
output.
Oscillation damping
phase
26.56
10 = 1 deg / 1 = 1 deg
Phase shift for oscillation damping function output.
0...360 deg
1.0 % / real32
Defines a gain for the output of the oscillation damping
function, ie. how much the output of the filter is
amplified before it is added to the torque reference.
Oscillation gain is scaled according to the speed
controller gain so that changing the gain will not
disturb oscillation damping.
Note: Before changing this parameter run-time, disable
the oscillation damping output using parameter
.
Monitor the behavior of
before re-enabling the
output.
Oscillation damping
gain
26.57
10 = 1 % / 10 = 1 %
Gain setting for oscillation damping output.
0.0 ... 100.0 %
- / real32
Displays the output of the oscillation damping function.
This value is added to the torque reference (as allowed
by parameter
26.52 Oscillation damping out enable
).
This parameter is read-only.
Oscillation damping
output
26.58
10 = 1 % / 1000 = 1 %
Output of the oscillation damping function.
-1600.000 ...
1600.000 %
- / real32
Displays the value of torque reference source 1
(selected by parameter
). See
the control chain diagram on page
This parameter is read-only.
Torque reference act
1
26.70
- / -
Value of torque reference source 1. For scaling, see
parameter
-1600.0 ... 1600.0 %
- / real32
Displays the value of torque reference source 2
(selected by parameter
). See
the control chain diagram on page
This parameter is read-only.
Torque reference act
2
26.71
- / -
Value of torque reference source 2. For scaling, see
parameter
-1600.0 ... 1600.0 %
- / real32
Displays the torque reference after the function applied
by parameter
(if any), and
after selection (
). See the
control chain diagram on page
.
This parameter is read-only.
Torque reference act
3
26.72
- / -
Torque reference after selection. For scaling, see
parameter
-1600.0 ... 1600.0 %
- / real32
Displays the torque reference after application of
reference additive 1. See the control chain diagram on
page
This parameter is read-only.
Torque reference act
4
26.73
Parameters 345
Содержание ACS880 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 ESP control program option N5600 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 16: ...16 ...
Страница 22: ...22 ...
Страница 24: ...24 ...
Страница 44: ...44 ...
Страница 66: ...66 ...
Страница 148: ...148 ...
Страница 167: ...Fieldbus control macro This application macro is not supported by the current firmware version Application macros 167 ...
Страница 168: ...168 ...
Страница 704: ...704 ...
Страница 728: ...728 ...
Страница 742: ...742 ...
Страница 762: ...762 ...