Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
Torque reference 1 /
uint32
Configures the selection between torque references 1
and 2.
See diagram at
.
0 = Torque reference 1
1 = Torque reference 2
Torque ref1/2
selection
26.14
0
0.
Torque reference 1
1
1.
Torque reference 2
2
Torque reference 1 is used when external control
location EXT1 is active. Torque reference 2 is used when
external control location EXT2 is active.
See also parameter
.
Follow Ext1/Ext2
selection
3
Digital input DI1 (
, bit 0).
DI1
4
Digital input DI2 (
, bit 1).
DI2
5
Digital input DI3 (
, bit 2).
DI3
6
Digital input DI4 (
, bit 3).
DI4
7
Digital input DI5 (
, bit 4).
DI5
8
Digital input DI6 (
, bit 5).
DI6
See
Terms and abbreviations (page 169)
Other [bit]
1.000 / real32
Defines the scaling factor for the torque reference (the
torque reference is multiplied by the value).
This allows drives sharing the load between two motors
on the same mechanical plant to be tailored to share
the correct amount each, yet use the same master
torque reference.
Load share
26.15
1000 = 1 / 1000 = 1
Torque reference scaling factor.
-8.000 ... 8.000
Zero / uint32
Selects the source of torque reference additive 1.
Note: For safety reasons, the additive is not applied
when an emergency stop is active.
See the control chain diagram on page
For the selections, see parameter
Torque additive 1
source
26.16
0.000 s / real32
Defines a low-pass filter time constant for the torque
reference.
Torque ref filter time
26.17
1000 = 1 s / 1000 = 1
s
Filter time constant for torque reference.
0.000 ... 30.000 s
0.000 s / real32
Defines the torque reference ramp-up time, ie. the time
for the reference to increase from zero to nominal
motor torque.
Torque ramp up
time
26.18
100 = 1 s / 1000 = 1 s
Torque reference ramp-up time.
0.000 ... 60.000 s
0.000 s / real32
Defines the torque reference ramp-down time, ie. the
time for the reference to decrease from nominal motor
torque to zero.
Torque ramp down
time
26.19
100 = 1 s / 1000 = 1 s
Torque reference ramp-down time.
0.000 ... 60.000 s
340 Parameters
Содержание ACS880 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 ESP control program option N5600 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 16: ...16 ...
Страница 22: ...22 ...
Страница 24: ...24 ...
Страница 44: ...44 ...
Страница 66: ...66 ...
Страница 148: ...148 ...
Страница 167: ...Fieldbus control macro This application macro is not supported by the current firmware version Application macros 167 ...
Страница 168: ...168 ...
Страница 704: ...704 ...
Страница 728: ...728 ...
Страница 742: ...742 ...
Страница 762: ...762 ...