Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
0
None
Zero
1
1.1 Motor speed used (page 174)
Motor speed used
3
1.6 Output frequency (page 174)
.
Output frequency
4
Motor current
6
Motor torque
7
.
DC voltage
8
Power inu out
10
23.1 Speed ref ramp input (page 311)
.
Speed ref ramp in
11
23.2 Speed ref ramp output (page 311)
.
Speed ref ramp out
12
24.1 Used speed reference (page 318)
Speed ref used
13
26.2 Torque reference used (page 338)
.
Torq ref used
14
28.2 Frequency ref ramp output (page 347)
.
Freq ref used
16
40.1 Process PID output actual (page 420)
Process PID out
17
40.2 Process PID feedback actual (page 420)
.
Process PID fbk
18
40.3 Process PID setpoint actual (page 420)
Process PID act
19
40.4 Process PID deviation actual (page 420)
.
Process PID dev
See
Terms and abbreviations (page 169)
Other [value]
20
1.70 Ambient temperature % (page 177)
The amplitude range of 0…100% corresponds to
0…60 °C or 32…140 °F.
Ambient
temperature
100.00 / real32
Defines the signal value that corresponds to 100%
amplitude.
AL2 signal scaling
36.7
1 = 1 / 100 = 1
Signal value corresponding to 100%.
0.00 ... 32767.00
- / uint16
Determines whether amplitude loggers 1 and 2 are
active continuously or only when the drive is
modulating.
Logger function
36.8
0 = Amplitude logger 1 active continuously
1 = Amplitude logger 1 active only when the drive is
modulating
AL1
b0
0 = Amplitude logger 2 active continuously
1 = Amplitude logger 2 active only when the drive is
modulating
AL2
b1
Reserved
b2…15
1 = 1
0000h…FFFFh
Done / uint16
Resets the peak value logger and/or amplitude logger
2.
(Amplitude logger 1 cannot be reset.)
Reset loggers
36.9
0
Reset completed or not requested (normal operation).
Done
1
Reset both the peak value logger and amplitude logger
2.
All
2
Reset the peak value logger.
PVL
Parameters 413
Содержание ACS880 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 ESP control program option N5600 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 16: ...16 ...
Страница 22: ...22 ...
Страница 24: ...24 ...
Страница 44: ...44 ...
Страница 66: ...66 ...
Страница 148: ...148 ...
Страница 167: ...Fieldbus control macro This application macro is not supported by the current firmware version Application macros 167 ...
Страница 168: ...168 ...
Страница 704: ...704 ...
Страница 728: ...728 ...
Страница 742: ...742 ...
Страница 762: ...762 ...