Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
0.0 s / uint32
Defines the activation delay for digital input DI3.
*DI status
**Delayed
DI status
t
On
t
Off
t
On
t
Off
Time
1
0
1
0
t
On
=
t
Off
=
*Electrical status of digital input. Indicated by
**Indicated by
DI3 ON delay
10.9
10 = 1 s / 10 = 1 s
Activation delay for DI3.
0.0 ... 3000.0 s
0.0 s / uint32
Defines the deactivation delay for digital input DI3. See
parameter
DI3 OFF delay
10.10
10 = 1 s / 10 = 1 s
Deactivation delay for DI3.
0.0 ... 3000.0 s
0.0 s / uint32
Defines the activation delay for digital input DI4.
*DI status
**Delayed
DI status
t
On
t
Off
t
On
t
Off
Time
1
0
1
0
t
On
=
t
Off
=
*Electrical status of digital input. Indicated by
**Indicated by
DI4 ON delay
10.11
10 = 1 s / 10 = 1 s
Activation delay for DI4.
0.0 ... 3000.0 s
0.0 s / uint32
Defines the deactivation delay for digital input DI4. See
parameter
DI4 OFF delay
10.12
10 = 1 s / 10 = 1 s
Deactivation delay for DI4.
0.0 ... 3000.0 s
Parameters 213
Содержание ACS880 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 ESP control program option N5600 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 16: ...16 ...
Страница 22: ...22 ...
Страница 24: ...24 ...
Страница 44: ...44 ...
Страница 66: ...66 ...
Страница 148: ...148 ...
Страница 167: ...Fieldbus control macro This application macro is not supported by the current firmware version Application macros 167 ...
Страница 168: ...168 ...
Страница 704: ...704 ...
Страница 728: ...728 ...
Страница 742: ...742 ...
Страница 762: ...762 ...