Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
Fieldbus adapter A configuration.
FBA A settings
51
None / uint16
Displays the type of the connected fieldbus adapter
module.
FBA A type
51.1
0 = Module is not found or is not properly connected,
or is disabled by parameter
; 1 = FPBA;
32 = FCAN; 37 = FDNA; 101 = FCNA, 128 = FENA-11/21;
135 = FECA; 136 = FEPL; 485 = FSCA.
This parameter is read-only.
- / uint16
Parameters
are adapter module-specific.
For more information, see the documentation of the
FBA A Par2
51.2
fieldbus adapter module. Note that not all of these
parameters are necessarily in use.
1 = 1 / 1 = 1
Fieldbus adapter configuration parameter.
0...65535
…
…
…
…
- / uint16
See parameter
.
FBA A Par26
51.26
1 = 1 / 1 = 1
Fieldbus adapter configuration parameter.
0...65535
Done / uint16
Validates any changed fieldbus adapter module
configuration settings. After refreshing, the value
reverts automatically to
FBA A par refresh
51.27
Note: This parameter cannot be changed while the
drive is running.
0
Refreshing done.
Done
1
Refreshing.
Refresh
0 / uint16
Displays the parameter table revision of the fieldbus
adapter module mapping file (stored in the memory of
the drive).
FBA A par table ver
51.28
In format axyz, where ax = major table revision number;
yz = minor table revision number.
This parameter is read-only.
1 = 1
Parameter table revision of adapter module.
0000…FFFFh
- / uint16
Displays the drive type code in the fieldbus adapter
module mapping file (stored in the memory of the
drive).
FBA A drive type
code
51.29
This parameter is read-only.
- / uint16
Displays the fieldbus adapter module mapping file
revision stored in the memory of the drive in decimal
format.
FBA A mapping file
ver
51.30
This parameter is read-only.
Not configured /
uint16
Displays the status of the fieldbus adapter module
communication.
D2FBA A comm
status
51.31
0
Adapter is not configured.
Not configured
1
Adapter is initializing.
Initializing
2
A timeout has occurred in the communication between
the adapter and the drive.
Time out
472 Parameters
Содержание ACS880 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 ESP control program option N5600 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 16: ...16 ...
Страница 22: ...22 ...
Страница 24: ...24 ...
Страница 44: ...44 ...
Страница 66: ...66 ...
Страница 148: ...148 ...
Страница 167: ...Fieldbus control macro This application macro is not supported by the current firmware version Application macros 167 ...
Страница 168: ...168 ...
Страница 704: ...704 ...
Страница 728: ...728 ...
Страница 742: ...742 ...
Страница 762: ...762 ...