By changing the parameters X, Y and Z on the
Orthogonal Sections
panel, the section plane can be
positioned at liberty within the specimen.
The position of the section plane is shown by colored lines.
Fig. 4-120
☞
The XY plane (blue) corresponds to the slice planes of the stack.
The position of section planes can be changed in various ways:
By shifting the sliders on the
Orthogonal Sections
panel.
X and Y settings may range from 1 up to the maximum number of pixels scanned (in the example
shown: 512).
Z settings may range from 1 to a maximum of n, with n standing for the number of slices in the stack
produced.
If you move the cursor into the image window, it changes into a crosshairs symbol
. By dragging this
symbol with the mouse you can position the XZ and YZ section planes to any point of intersection
with the XY plane. A click with the left mouse button places the intersection to the desired position.
If you move the crosshair symbol
onto the intersection of the red and green section planes, it
changes into the:
symbol. If you now press the left mouse button and keep it pressed you can
reposition both section planes
at a time
.
If you move the crosshairs symbol
onto the green section plane, it changes into the
symbol. If
you now press the left mouse button and keep it pressed, you can reposition the (green) XZ section
plane.
Summary of Contents for LSM 510 Inverted
Page 1: ...I LSM 510 Laser Scanning Microscope Operating Manual...
Page 4: ...INTRODUCTION LSM 510 IV B 40 051 e 07 98...
Page 10: ...INTRODUCTION LSM 510 X B 40 051 e 07 98...
Page 12: ...NOTES ON DEVICE SAFETY Contents LSM 510 1 2 B 40 051 e 07 98...
Page 22: ...NOTES ON DEVICE SAFETY Warning and information labels LSM 510 1 12 B 40 051 e 07 98...
Page 24: ...LSM 510 SETUP REQUIREMENTS Contents LSM 510 2 2 B 40 051 e 07 98...
Page 34: ...LSM 510 SETUP REQUIREMENTS Laser Module VIS Laser Module UV LSM 510 2 12 B 40 051 e 07 98...
Page 36: ...INTRODUCTION TO LASER SCANNING MICROSCOPY Contents LSM 510 3 2 B 40 051 e 07 98...
Page 48: ...INTRODUCTION TO LASER SCANNING MICROSCOPY Contents LSM 510 3 2 B 40 051 e 07 98...
Page 231: ...OPERATION LSM 510 Annex B 40 051 e 07 98 4 173 Fig 4 171 Change over of the Scanning Module...
Page 256: ...INTRODUCTION TO LASER SCANNING MICROSCOPY Contents LSM 510 5 2 B 40 051 e 07 98...