1-3
IM 760301-01E
11
2
3
4
5
6
7
8
9
10
11
12
App
Index
Names and Functions of Parts
1.2
Setup Menu Display Key and Execution Key
Setting the Measurement Conditions
SENSOR RATIO
MEASURING
RMS
MEAN
DC
RMEAN
CURRENT RANGE
VOLTAGE RANGE
MEASURING
RMS
MEAN
DC
RMEAN
ALL
INPUT INFO.
DISPLAY
ITEM & ELEMENT
2
3
4
COMPEN
ELEMENT
ELEMENT
1
WIRING
MODE
AUTO
MODE
AUTO
EXT SENSOR
• WIRING Key (See sections 4.1, 4.2, 5.7, and 5.8)
Displays a menu for selecting the wiring system, selecting independent setting of input
elements, setting the computing equation for efficiency, setting the wiring
compensation, setting the efficiency compensation, etc. When the wiring
compensation or efficiency compensation is enabled, the COMPEN indicator illuminates.
• SHIFT+WIRING (INPUT INFO.) Key (See sections 3.16 and 4.1)
Displays a list of conditions for receiving voltage/current signals and acquiring the
signals as data such as the wiring system of each input element, wiring unit,
measurement range, input filter, scaling, and synchronization source.
• ELEMENT Key (See section 4.1 and 4.2)
• Selects the input element for setting the measurement range. The selected input
element switches each time the ELEMENT key is pressed.
• Input elements that are assigned to the same wiring unit in the wiring system
selection are selected simultaneously.
• SHIFT+ELEMENT (ALL) Key (See section 4.1 and 4.2)
Collectively sets the voltage range or current range of all installed input elements.
Pressing only the ELEMENT key again enables individual input elements to be configured.
•
Key and Key (See section 4.3 and 4.4)
Selects the voltage range, the current range, or the current sensor range. The
selected range is enabled when the AUTO key is not turned ON (manual range function).
• AUTO Key (See section 4.3 and 4.4)
When the AUTO key is pressed and the AUTO indicator illuminates, the auto range
function is enabled. The voltage range, current range, and current sensor range are
automatically switched according to the amplitude of the input electric signal. Pressing
the AUTO key again turns OFF the AUTO indicator and enables the manual range function.
• EXT SENSOR Key (See section 4.4)
When the EXT SENSOR key is pressed and the “EXT SENSOR” indicator illuminates,
the current sensor range for measuring the current sensor output on the WT3000 can
be selected using the
or
key in the CURRENT RANGE section. Pressing the
EXT SENSOR key again turns OFF the EXT SENSOR indicator and enables the
selection of the current range for direct input.
• SHIFT+EXT SENSOR (SENSOR RATIO) Key (See section 4.4)
Displays a menu for setting the current sensor transformation ratio for each input
element. These transformation ratios are used to convert the current sensor output to current.