15-32
IM 701240-01E
Note
•
Depending on the operation condition of the SL1400 (such as when measurement is in
progress), data save and setup data load operations may not be possible.
•
When data is being saved or the setup data is being loaded, other Web server functions
cannot be used.
•
When loading the setup data or when aborting the save operation, a temporary file
(zzzftpzzztmpzzz.bat) is created in the start directory of the Internet Explorer. After the
operation is complete, the temporary file will be deleted.
•
If you execute the data save operation when there is no waveform data or waveform
parameter, an error is displayed on the SL1400 screen, and a 0-byte file is saved.
Controlling the SL1400 (Instrument Control)
You can use the PC to set the display format and the data save conditions of the
SL1400. The settings entered here apply to the display format and save conditions
used to save the data on the previous page
• Starting/Stopping the Waveform Acquisition (Acquisition)
Start
Click
Start
to start the waveform acquisition.
Stop
Click
Stop
to stop the waveform acquisition.
• Turning ON/OFF the Waveform Display and Setting the Vertical Position
(Channel)
Selecting the Target Waveform
From the channel box, select the channel for turning ON/OFF the display and
setting the vertical position from the following:
Chan1 to Chan16 (channels 1 to 16)
Display ON/OFF
To display the waveform of the selected channel (turn it ON), select the Display check
box. Clear the check box to not display the waveform of the selected channel (OFF).
Vertical Position
You can set the vertical position of the waveform of the selected channel. For a
description of the selectable range of the vertical position, see section 5.4.
• Setting the Display Format (Display)
Display Format
Select the number of divided windows when displaying waveforms from the
following:
1 Zone, 2 Zone, 3 Zone, 4 Zone, 8 Zone, and 16 Zone
For the meanings of the selections, see the explanation in section 8.1.
Turning ON/OFF the Display of the Waveform Labels and Scale Values
(Label)
• Display Waveform Label (TraceLabel)
To display the labels of the displayed waveforms, select the TraceLabel check
box. Clear the check box to not display the labels.
• Turning ON/OFF the Display of the Upper and Lower Limits of the Displayed
Waveforms (ScaleValue)
To display the upper and lower limits of the displayed waveforms, select the
ScaleValue check box. Clear the check box to not display the upper and lower
limits.
15.7 Using the Web Server Function