6-35
IM 701240-01E
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
App
Index
Triggering
Setting the Bit Patterns of Logic A and Logic B
(Only when using logic input channels)
11.
Press the
Logic Pattern
soft key. The Logic Pattern setup dialog box appears.
12.
Use
jog SELECT
to select the pattern of each bit (Bit A1 to Bit A8 and
Bit B1 to Bit B8) from H, L, and X.
Setting the Trigger Level
13.
Press the
Select CH
soft key. The channel selection menu appears.
14.
Use
jog SELECT
to set the channel to assign the trigger level.
15.
Press the
Level
soft key.
16.
Use
jog SELECT
to set the trigger level.
17.
Likewise, set the trigger level for all channels on which patterns were assigned
in step 9.
Note
The trigger level setting applies to both simple and enhanced triggers.
Setting the Hysteresis
18.
Press the
Hysteresis
soft key to select
,
, or
.
Note
The pattern settings of conditions B apply to all trigger types.
6.15 Setting the Period Trigger (ENHANCED)