![Yamatake DigitroniK DCP32 User Manual Download Page 189](http://html.mh-extra.com/html/yamatake/digitronik-dcp32/digitronik-dcp32_user-manual_905225189.webp)
Chapter 10. SPECIFICATIONS
Item
Output
2G output 1
5G outputs 1, 2
5K outputs 1, 2, 3
Auxiliary output
5G outputs 1, 2
5K outputs 1, 2, 3
(when current out-
put is switched to
voltage output)
Event/
Events 1, 2
Time
Event
Output
Event 3
Time events 1 to 5
Specification
Contact type:
1a (2 circuits)
Contact rating:
2.5A (30 Vdc, L/R=0.7 ms)
4A (120 Vac, cosø=0.4)
2A (240 Vac, cosø=0.4)
Allowable contact voltage: 250 Vac, cosø=0.4
125 Vdc, L/R=0.7 ms
Max. switching power:
75 W (L/R=0.7 ms)
480 VA (cosø=0.4)
Life:
100,000 operations
(cosø=0.4 at contact rating, frequency: 30
operations/minute)
Min. switching voltage:
5 V
Min. switching current:
100 mA
MFB (motor feedback) input range:
100 to 2500
Ω
Control at MFB (motor feedback) disconnection:
ON/OFF for continuation of operation
according to MFB estimated position can be
selected.
Output current:
4 to 20 mA dc/0 to 20 mA dc
Allowable load resistance: 600
Ω
max. (under operating conditions)
Output accuracy:
±0.1%FS max. (under standard conditions)
Note that output accuracy becomes
±0.5%FS when 0 to 20 mA output is 5% or
less.
Output resolution:
1/10000
Inrush current:
25 mA max for 50 ms max. (at 250
Ω
load)
Max. output current:
22.0 mA dc
Min. output current:
0.0 mA dc
Output updating cycle:
0.1 seconds
Open terminal voltage:
25 V max. (output 1)
18 V max. (output 2, output 3, auxiliary out-
put)
Allowable load resistance: 600
Ω
max. (under operating conditions)
Inrush current:
25 mA max for 50 ms max. (at 250
Ω
load)
Load current adjustment: 2 to 22 mA variable
Open terminal voltage:
25 V max. (output 1)
18 V max. (output 2, output 3)
OFF leakage current:
100 µA max.
Output response time:
At ON-OFF 600
Ω
load: 0.5 ms max.
At OFF-ON 600
Ω
load: 1.0 ms max.
Output resolution:
1/1000
Time-proportional cycle:
1 to 60 seconds variable
Contact type:
1a
Contact rating:
1A (240 Vac/30 Vdc, resistive load)
Life:
100,000 operations (at rating)
Min. switching voltage, current:
10 V, 10 mA
Contact type:
1a1b
Contact rating:
2A (240 Vac/30 Vdc, resistive load)
Life:
100,000 operations (at rating)
Min. switching voltage, current:
10 V, 10 mA
External supply voltage:
10 to 29 Vdc
Max. load current:
70 mA/load
OFF leakage current:
0.1 mA max.
ON residual voltage:
1.6 V max.
M/M drive relay
Current output
Voltage output
Relay contact output
Relay contact output
Open-collector out-
put
10-5