Chapter 8. PROGRAM SETUP
■
Setting up G.Soak (guarantee soak) (CH2) items
①
In the setting display state, move to the G.Soak (CH2) item of the segment to
be set up on the programming map.
②
If you press the
ENT
key, the lower display starts blinking to indicate start of
entry to the No.1 setup.
③
Press the
↑
,
↓
,
←
or
→
key to set to the G.Soak width (CH2) setting.
Setting range: 0 to 1000U
④
When you press the
ENT
key, blinking on the lower display stops.
(When the
FUNC
key + the
CLR
key are pressed, the lower display returns to
“- - - -” and blinking stops.)
●
Display
• “- - - -” is displayed for the setting values in non-set segments.
The G.Soak function on channel CH2 does not work in non-set segments.
• When setup data
C70
is set to 1, G.Soak (CH2) items on the programming map
are skipped and not displayed.
• The profile display displays the trend of the SP pattern on the channel currently
selected in the basic display state.
G.Soak (CH2) setting value
PROG
SEG
PROFILE
Program
No.
Segment
No.
Pattern
tendency
EV1 to EV3 and T1 to T5 all out