![Yamatake DigitroniK DCP32 User Manual Download Page 156](http://html.mh-extra.com/html/yamatake/digitronik-dcp32/digitronik-dcp32_user-manual_905225156.webp)
8-8
Chapter 8. PROGRAM SETUP
●
When event type is controller status event
In this case, the event item on the programming map is skipped and not displayed.
■
Setting up time events 1 to 5
①
In the setting display state, move to the event 1 to 5 items of the segment to be
set up on the programming map.
②
If you press the
ENT
key, the upper display starts blinking to indicate start of
entry to the No.1 setup.
③
Press the
↑
,
↓
,
←
or
→
key to set to the No.1 setup ON time setting.
Setting range: 0:00 to 99:59
(Select either of hours:minutes or minutes:seconds as the time unit in setup data
C64
. “:” is substituted by “.” as it cannot be displayed.)
④
When you press the ENT key, blinking on the upper display stops. The lower
display then starts blinking to indicate start of entry to the No.2 setup.
(When the
FUNC
key + the
CLR
key are pressed, “- - - -” is redisplayed on
both the upper and lower displays and blinking stops.)
⑤
Press the
↑
,
↓
,
←
or
→
key to set to the No.2 setup ON time setting.
Setting range: ON time s 0:01 to 99:59
⑥
When you press the
ENT
key, blinking on the upper display stops.
(When the
FUNC
key + the
CLR
key are pressed, “- - - -” is redisplayed on the
upper display and blinking stops.)
●
Display
• “- - - -” is displayed for the setting values in non-set segments.
• On models that do not support time events, event 1 to 5 items on the
programming map are all skipped and not displayed. The table below shows
time events by a
«
.
• When setup data
C69
is set to 1, event 1 to 5 items on the programming map are
all skipped and not displayed.
ON time setting value
PROG
SEG
PROFILE
Program
No.
Segment
No.
Pattern
tendency
EV1 to EV3 all lit. LEDs corresponding to T1 to T5 lit.
OFF time setting value
Time event No.
tt setting value
T1
T2
T3
T4
T5
0
«
«
«
«
«
1
«
«
«
«
2
«
«
«
3
«
«
4
«
5