![Yamatake DigitroniK DCP32 User Manual Download Page 185](http://html.mh-extra.com/html/yamatake/digitronik-dcp32/digitronik-dcp32_user-manual_905225185.webp)
10-1
Chapter 10. SPECIFICATIONS
10 - 1
Specifications
Item
Program
Number of programs
Number of segments
Segment setting system
Segment time
Basic time accuracy
Events (3)
Time events (5)
PID set No. (2CH)
G.Soak (2CH)
PV start
Cycle
Pattern link
Tag
Input 1
Input type
Input readout accuracy
Input sampling cycle
Input bias current
Input impedance
Measuring current
Influence of wiring
resistance
RTD input allowable wiring
resistance
Allowable parallel
resistance
Specification
19
30 per program
RAMP-X system: Set by set points (SP1, SP2) and time.
0 to 99 hours 59 minutes, or 0 to 99 minutes 59 seconds (time unit selectable)
±0.01% (0.1 second delay when segment time setting is 0)
Sets operating point.
Sets ON and OFF times.
Sets 0 to 8 (Set 0 for continuation of previous segment) (Set 0 to 4 on heat/cool mod-
els.)
Sets G.Soak width 0 to 1000U.
Sets program ON/OFF and channel.
Sets program count 0 to 9999.
Sets program No.0 to 19 (0: no link)
Sets 8 alphanumerics for each program (not displayed on controller)
Thermocouple, resistance temperature detector, DC voltage, DC current multi-range
(See pages 2-8 and 2-9.)
±0.1%FS±1U (varies according to standard conditions, display value conversion and
range)
• At -100°C max. of K and T thermocouples:
±1°C±1U
• At 260°C max. of B thermocouple:
±4.0%FS±1U
At 260 to 800°C:
±0.4%FS±1U
At 800 to 1800°C:
±0.2%FS±1U
• At 100°C max. of R and S thermocouples: ±0.2%FS±1U
At 100 to 1600°C:
±0.15%FS±1U
• At 300°C max. of PR40-20 thermocouple:
±2.5%FS±1U
At 300 to 800°C:
±1.5%FS±1U
At 800 to 1900°C:
±0.5%FS±1U
• Golden iron chromel thermocouple:
±1.5K±1U
• F01, F33, F38, P01, P33 and P38 ranges by resistance thermometer detector input:
±0.15%±1U
• At 0 to 10 mV range:
±0.15%FS±1U
• At -100°C max. of DIN U thermocouple:
±2°C±1U
At -100 to 0°C:
±1°C±1U
• At -100°C max. of DIN L thermocouple:
±1.5°C±1U
0.1 seconds
Thermocouple, DC voltage input: ±1.3 µA max. (at peak value, under standard condi-
tions)
At 1 V min. range: -3 µA max.
DC current input:
50
Ω
±10% (under operating conditions)
RTD input:
1.04 mA ±0.02 mA, current flow from terminal A (under operating
conditions)
Thermocouple, DC voltage input: Changes in readout value at wiring resistance of
250
Ω
at both ends are as follows by input conver-
sion:
• 0 to 10 mV, -10 to +10 mV:
Within 35 µV
• 0 to 100 mV: Within 60 µV
• Other:
Within 750 µV
RTD input:
±0.01%FS/
Ω
max. in wiring resistance range 0 to 10
Ω
Range of F01, F33, F38, P01, P33 and P38:
±0.02%FS/
Ω
max.
• Allowable wiring resistance is 85
Ω
max. (including Zener barrier resistance. When
Zener barrier is used, this applies only to ranges other than F01, F33, F38, P01, P33
and P38. Note that site adjustment is required.)
• Allowing wiring resistance is 10
Ω
max. (This applies to ranges F01, F33, F38, P01,
P33 and P38. Note that the Zener barrier cannot be used.)
Thermocouple disconnection detection allowable parallel resistance: 1 M
Ω