2-23
TECH
FEA
Technical features and description
Propeller damper cooling (F250G and FL250G)
The water pipe for cooling the propeller damper is incorporated in the lower case. The water intake
is located in front of the trim tab to drawn in the water by the dynamic pressure, and the propeller
damper is cooled without disturbing the exhaust gas flow. As a result, higher output can be
obtained.
È
Cooling water flow
1
Water pipe
È
1
Summary of Contents for F200B