5-52
5
7.
Check the Rectifier Regulator for conti-
nuity.
OL: Indicates an overload
8.
Connect the Rectifier Regulator couplers
and ground lead, and then install the fuse
holder.
9.
Install the intake manifold (STBD). See
“Installing the intake manifold” (6-18).
d
e
f
g
h
k
d
e
f
g
h
k
R
R
G
G
G
B
Rectifier Regulator continuity
(testing diode mode):
Tester probe
Display value
(reference data)
d
e
OL
f
g
h
k
e
d
OL
f
g
h
k
f
d
0.420
V
e
0.422
V
g
OL
h
k
g
d
0.426
V
e
0.421
V
f
OL
h
k
h
d
0.425
V
e
0.424
V
f
OL
g
k
k
d
0.756
V
e
0.755
V
f
0.416
V
g
0.417
V
h
0.417