1-9
SPEC
Specification
VCT system
PTT system
With remote control lever
fully closed
APS 1
V
0.550–0.850
APS 2
V
0.400–1.000
With remote control lever
fully open
APS 1 and APS 2
V
Above 3.250
TPS
Output voltage (*1)
With throttle valve fully
closed
TPS 1
V
0.500–0.700
With throttle valve fully
open
TPS 2
V
4.600–4.700
Shift cut switch
Input voltage
V
4.75–5.25
(*1) The figures are for reference only.
Item
Unit
Model
F200BET FL200BET F250GET FL250GET
OCV
Resistance (*1)
At 20 °C (68 °F)
Ω
6.7–7.7
Input voltage
V
12.0
(*1) The figures are for reference only.
Item
Unit
Model
F200BET FL200BET F250GET FL250GET
Trim sensor
Free position resistance (*1)
At 20 °C (68 °F)
Ω
247.6–387.6
Setting resistance
Ω
9.0–11.0
(*1) The figures are for reference only.
Item
Unit
Model
F200BET FL200BET F250GET FL250GET
Summary of Contents for F200B
Page 1: ...F200B FL200B F250G FL250G SERVICE MANUAL 6DX 28197 5P 11 ...
Page 4: ......
Page 21: ...0 16 0 Tilt rod wrench 90890 06569 Special service tool ...
Page 207: ...5 78 5 MEMO PTT electrical system ...
Page 359: ...7 100 7 MEMO Cylinder block ...
Page 386: ...LOWR Lower unit 8 23 2 Install the rubber seal 1 1 ...
Page 407: ...8 44 8 Shim location F250G P F R T3 T1 T2 T4 Shimming regular rotation model ...
Page 461: ...8 98 8 Shim location FL250G F R P T3 T4 T2 T1 Shimming counter rotation model ...
Page 473: ...8 110 8 MEMO Shimming counter rotation model ...
Page 566: ...A 1 MEMO ...
Page 569: ......