April 2017
2-459
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
059-383
Status Indicator RAPs
Launch Issue
059-383 Warm Up Time Fail RAP
BSD-ON:
BSD 10.1 Fusing Heat Control (1 of 2)
BSD-ON:
BSD 10.2 Fusing Heat Control (2 of 2)
010-383 When transitioning from the wait state, the specified temperature is not reached within
the specified time.
NOTE: This fault may occur when the temperature in the installation environment is low (10
degrees C or lower).
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
Ensure that the fuser is installed correctly.
3.
Check the drawer connector between the fuser and the main unit (
DP612
) for damage.
4.
Check the connections and wiring between the fuser (
DP612
) and the LVPS (
P2
) for an
open circuit, short circuit or poor contact.
5.
Check the connections and wiring between the fuser (DP612S) and the drive PWB (
P/
J416
) for an open circuit, short circuit or poor contact.
6.
If the fault persists, install new components as necessary:
•
Fuser,
PL 10.05 Item 2
.
•
LVPS,
PL 1.10 Item 8
.
•
Drive PWB,
PL 1.10 Item 3
.