April 2017
2-574
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
127-353 to 127-399, 127-337
Launch Issue
Status Indicator RAPs
127-353 to 127-399 Fatal Error RAP
127-353 Fatal error related to LPD.
127-354 Fatal error of FTP server was detected.
127-396 Fatal error related to mail IO.
127-398 Fatal error related to IPP.
127-399 Fatal error related to JME.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
Perform the
016A
Scan to Network Error Entry RAP.
127-337 Job Template HDD Write Error RAP
127-337 An error occurred when the job template was stored on the HDD.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
Check the wiring between the ESS PWB,
PL 3.10 Item 6
and the hard disk.
3.
Ensure that all connectors on the drive PWB,
PL 1.10 Item 3
and the ESS PWB,
PL 3.10
Item 6
are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
4.
Initialise the hard disk. Refer to
dC355
Hard Disk Diagnostics.
5.
Initialize the Sys - System NVM, refer to
dC301
.
6.
Reload the software,
GP 4
.
7.
Perform the
OF2
Special Boot Modes RAP.
8.
If the fault persists, install a new components as necessary:
•
Hard disk,
PL 3.10 Item 2
.
•
ESS PWB,
PL 3.10 Item 6
.