April 2017
2-443
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
041-310, 041-333
Status Indicator RAPs
Launch Issue
041-310 IM Logic Fail RAP
BSD-ON:
BSD 3.1 PWB Communications (ESS PWB to Drive PWB)
041-310 IM software control error detected.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
Reload the software,
GP 4
.
3.
If the fault persists, install new components as necessary:
•
Drive PWB,
PL 1.10 Item 3
.
•
ESS PWB,
PL 3.10 Item 6
.
041-333 Drive PWB F10 Blown RAP
BSD-ON:
BSD 1.5 DC Power Generation (2 of 2)
BSD-ON:
BSD 1.7 Option DC Power Distribution
041-333 Drive PWB fuse 10 open circuit was detected.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Check the tray module for overcurrent and overvoltage. Repair the wiring or install new
components as necessary.
2.
After the faulty circuit has been repaired, install a new drive PWB,
PL 1.10 Item 3
.