April 2017
2-74
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
012-302, 012-302A
Launch Issue
Status Indicator RAPs
012-302 Front Cover Interlock Open Entry RAP
012-302 The front cover interlock open was detected.
Procedure
Go to the relevant procedure:
•
Integrated office finisher installed,
012-302A
Front Cover Interlock Open RAP.
•
Office finisher LX installed,
012-302B
Front Cover Interlock Open RAP.
012-302A Front Cover Interlock Open RAP
BSD-ON:
BSD 12.1 Integrated Office Finisher DC Power and Interlock Switching
Initial Actions
NOTE: Ensure the correct RAP is performed, refer to the
012-302
Front Cover Interlock Open
Entry RAP.
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
•
Check that the front cover can be opened and closed.
•
Check that the finisher front interlock switch,
PL 12.14 Item 12
is correctly installed and
undamaged.
•
Switch off, then switch on the machine,
GP 10
.
Procedure
Enter
dC330
code 012-302. Open, then close the front cover to actuate the finisher front inter-
lock switch. The display changes.
Y
N
Check the connections of
P/J8702
and
P/J8733
. The connectors are good.
Y
N
Secure the connections.
Check for an open or short circuit between
P/J8702
and
P/J8733
. The wiring is good.
Y
N
Repair the open or short circuit.
Measure the voltage between the finisher PWB
P/J8702
pin 4 (+) and ground (-). Open,
then close the front cover to actuate the finisher front interlock switch. The voltage
changes.
Y
N
Install a new finisher front interlock switch,
PL 12.14 Item 12
.
Check the wires and connectors for an intermittent open or short circuit. If the fault per-
sists, install a new finisher PWB,
PL 12.14 Item 1
.
Measure the voltage between the finisher PWB
P/J8702
pin 1 (+) and (-). The voltage is
approxi24VDC.
Y
N
Check the +24VDC circuit. Refer to the
Wiring Diagrams
.
Check the wires and connectors for an intermittent open or short circuit. If the fault persists,
install a new finisher PWB,
PL 12.14 Item 1
.