April 2017
2-573
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
127-310 to 127-315, 342, 127-320
Status Indicator RAPs
Launch Issue
127-310 to 127-315, 342 ESS Error RAP
127-310 A fatal error occurred in ESR task.
127-311 Fatal error related to ExtPRTc.
127-312 DFE detected a video link error.
127-313 ESS detected a video link error.
127-314 ESS detected a video link error.
127-315 A problem has occurred with software processing, causing the processing to stop.
127-342 A response such as system function recall error was detected.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
Ensure that all connectors on the drive PWB,
PL 1.10 Item 3
and the ESS PWB,
PL 3.10
Item 6
are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
3.
Reload the software,
GP 4
.
4.
Perform the
OF2
Special Boot Modes RAP.
127-320 DFE Critical Fail RAP
127-320 An error occurred in the connection to the DFE. Or the DFE needs to treat the device
as SystemFail.
Procedure
Advise the customer to:
1.
To take the corrective actions based on the fault code displayed in the DFE monitor, then
reboot the system.
2.
Check the device settings.
3.
Check the connection to the DFE.
4.
Check the DFE hardware.