April 2017
2-66
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
012-211A, 012-221, 012-223
Launch Issue
Status Indicator RAPs
Y
N
Secure the connections.
Check for an open or short circuit between
P/J8711
and
P/J8736
. The wiring is good.
Y
N
Repair the open or short circuit.
Enter
dC330
code 012-060. Measure the voltage between the finisher PWB
P/J8711
pin
1 (+) and ground (-). The voltage changes.
Y
N
Check the +24VDC circuit. Refer to the
Wiring Diagrams
. If the fault persists, install
a new finisher PWB,
PL 12.14 Item 1
.
Enter
dC330
code 012-061. Measure the voltage between the finisher PWB
P/J8711
pin
2 (+) and ground (-). The voltage changes.
Y
N
Check the +24VDC circuit. Refer to the
Wiring Diagrams
. If the fault persists, install
a new finisher PWB,
PL 12.14 Item 1
.
Check the wires and connectors for an intermittent open and short circuit. If the fault per-
sists, install a new stacker motor,
PL 12.20 Item 9
.
Check the wires and connectors for an intermittent open or short circuit. If the fault persists,
install a new finisher PWB,
PL 12.14 Item 1
.
012-221, 012-223 Front Tamper Home Sensor Fail Entry
RAP
012-221 The front tamper home sensor failed to actuate within the specified time.
012-223 The front tamper home sensor failed to deactuate within the specified time.
Procedure
Go to the relevant procedure:
•
Integrated office finisher installed,
012-221A, 012-223A
Front Tamper Home Sensor Fail.
RAP
•
Office finisher LX installed,
012-221B, 012-223B
Front Tamper Home Sensor Fail RAP.
B