April 2017
2-565
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
124-345, 124-346, 348, 354
Status Indicator RAPs
Launch Issue
124-345 Billing Meter Type Restoration Fail RAP
124-345 Billing meter type fail (one mismatches the others but cannot be automatically
repaired.)
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Switch off, then switch on the machine,
GP 10
. The fault persists.
Y
N
Perform
SCP 5
Final Actions.
Enter
dC131
. Compare NVM values 720-002 and 720-062. Both values are different.
Y
N
Install a new drive PWB,
PL 1.10 Item 3
.
Install a new ESS PWB,
PL 3.10 Item 6
.
124-346, 348, 354 Information Mismatch RAP
124-346 Billing count type fail (all the three are different from each other).
124-348 Modal break point fail (all the three are different from each other).
124-354 Territory info fail (contents corrupted, the controller pwb was replaced).
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
If the fault persists, install a new components as necessary:
•
ESS PWB,
PL 3.10 Item 6
.
•
Drive PWB,
PL 1.10 Item 3
.