April 2017
2-510
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
116-348, 349, 358, 360, 374, 116-353, 354, 356, 361, 362
Launch Issue
Status Indicator RAPs
116-348, 349, 358, 360, 374 Redirecter Fail RAP
116-348 Various fatal errors detected in the redirecter.
116-349 An error occurred when calling the Pflite function using the SIF.
116-358 Fatal error related to salutation.
116-360 Fatal error related to SMB.
116-374 Fatal error of auto SW.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Advise the customer to check that the TCP/IP ports are correctly configured.
2.
Switch off, then switch on the machine,
GP 10
.
3.
Ensure that all connectors on the drive PWB,
PL 1.10 Item 3
and the ESS PWB,
PL 3.10
Item 6
are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
4.
Reload the software,
GP 4
.
5.
Perform the
016A
Scan to Network Error Entry RAP.
6.
Perform the
OF2
Special Boot Modes RAP.
116-353, 354, 356, 361, 362 HDD Fail RAP
116-353 The HDD was not booted due to a physical HDD failure detected on booting.
116-354 The M/C was not started up due to a product code error detected in the HDD on boot-
ing.
116-356 The M/C was not started up due to an insufficient HDD capacity error detected during
HDD formatting.
116-361 Fatal error of SPL HDD.
116-362 SSDP Software Fail.
Procedure
Perform the
016-210, 506, 777, 780, 798
HDD Error RAP.