Measure the voltage between the finisher PWB
P/J8705
pin 1 (+) and ground (-). The
voltage is approxi24VDC.
Y
N
Check the +24VDC circuit. Refer to the
Wiring Diagrams
. If the circuit is good, install
a new finisher PWB,
PL 12.14 Item 1
.
Enter
dC330
code 012-013. Measure the voltage between the finisher PWB
P/J8705
pin
2 (+) and ground (-). The voltage changes.
Y
N
Install a new finisher PWB,
PL 12.14 Item 1
.
Install a new sub paddle solenoid,
PL 12.10 Item 27
.
Check the wires and connectors for an intermittent open or short circuit. If the fault persists,
install a new finisher PWB,
PL 12.14 Item 1
.
012-152 Compiler Exit Sensor On Jam Entry RAP
012-152 The compiler exit sensor does not actuate within a specified time after receiving the
sheet exit command (the paper to be ejected has actuated the IOT exit sensor 1).
Procedure
Go to the relevant procedure:
•
Integrated office finisher installed,
012-152A
Compiler Exit Sensor On Jam RAP.
•
Office finisher LX installed,
012-151B, 012-152B
Compiler Exit Sensor On Jam RAP.
C