April 2017
2-98
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
012-935B
Launch Issue
Status Indicator RAPs
012-935B Entrance Sensor RAP
BSD-ON:
BSD 13.7 Office Finisher LX Transportation
Initial Actions
NOTE: Ensure the correct RAP is performed, refer to the
012-935
Entrance Sensor Entry RAP.
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
•
Check for obstructions in the paper path
•
Check that the finisher is docked correctly to ensure proper transport gate operation.
Procedure
Enter
dC330
code 012-100. Actuate the transport entrance sensor,
PL 13.35 Item 10
. The
display changes.
Y
N
Check the wiring between
J8868
pin 2 and
P/J8988
pin 2 for an open or short circuit, or
a loose or damaged connector. The wiring is good.
Y
N
Reconnect or repair as necessary.
Measure the voltage between
P/J8988
pins 3 and 1 on the finisher PWB. The voltage is
approxi5VDC.
Y
N
Install a new finisher PWB,
PL 13.45 Item 2
.
Measure the voltage between
P/J8988
pin 2 on the finisher PWB and ground. Actuate the
finisher entrance sensor. The voltage changes.
Y
N
Install a new transport entrance sensor,
PL 13.35 Item 10
Install a new finisher PWB,
PL 13.45 Item 2
.
Install a new finisher PWB,