April 2017
2-19
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
003-344, 003-345, 003-346
Status Indicator RAPs
Launch Issue
003-344 Hotline Fail RAP
003-344 Hotline failure during power on.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
Ensure that all connectors on the drive PWB,
PL 1.10 Item 3
and the ESS PWB,
PL 3.10
Item 6
are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
3.
Reload the software,
GP 4
.
4.
Perform the
OF2
Special Boot Modes RAP.
003-345, 003-346 X PIO Mismatch RAP
003-345 When a job fail was received from the IISS, an error of the X hot line was detected.
003-345 When IIT image delivered was received from the IISS, an error of the X hot line was
detected.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
Ensure that all connectors on the drive PWB,
PL 1.10 Item 3
and the ESS PWB,
PL 3.10
Item 6
are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
3.
Reload the software,
GP 4
.
4.
Perform the
OF2
Special Boot Modes RAP.