Status Indicator RAPs
016-358 Controller Parallel Card Fail RAP
016-358 Controller parallel port diagnostic fail.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
Reload the software,
GP 4
.
3.
If the fault persists, install a new ESS PWB,
PL 3.10 Item 6
.
016-359, 016-361 Controller USB Fail RAP
016-359 Cont USB HUB diagnostic fail.
016-361 Cont USB 3.0 device diagnostic fail.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Install a new ESS PWB,
PL 3.10 Item 6
.