April 2017
6-45
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
dC126
General Procedures and Information
Launch Issue
Figure 2 Registration test pattern side 2
5.
Compare the registration of the image on side 1 and side two of the print with the specifi-
cation in
IQ7
Registration. Compare the magnification of the image on side 1 and bide 2
of the print with the specification in
IQ8
Magnification. If any measurement does not meet
the specifications, go to
Registration Adjustment
.
Registration Adjustment
1.
This procedure uses side registration as an example. When performing other adjust-
ments, use the appropriate location on the test pattern. Refer to
Purpose
.
NOTE: The Sa and Sb locations marked on the test pattern indicate the distance from the
test pattern image to the edge of the paper.
2.
On the printed test pattern, measure the distance (in millimeters) at point Sa from the line
to the edge of the paper on side 1 and side 2. Refer to
Figure 1
and
Figure 2
.
3.
Touch Side Registration, then Adjusted Side (Side 1).
4.
Touch +/- to enter the measured value of position A for side 1.
NOTE: Touch A to open a keypad on which to enter the value.
5.
Touch Side Registration, then Adjusted Side (Side 2).
6.
Touch +/- to enter the measured value of position A for side 2.
NOTE: Touch B to open a keypad on which to enter the value.
7.
After inputting the values for side 1 and side 2, touch Adjust to save the settings.
8.
Exit diagnostics,
GP 1
.