April 2017
2-447
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
042-325, 042-330
Status Indicator RAPs
Launch Issue
042-325 Main Motor Fail RAP
BSD-ON:
BSD 4.1 Main Drive Control
042-325 Main motor run fault.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Refer to the procedure that follows as necessary:
•
GP 6
How to Check a Motor.
Enter
dC330
code 042-003 to run the main motor,
PL 40.10 Item 1
. The main motor runs.
Y
N
Check the +24V power supply to the main motor. The power supply is good.
Y
N
Check the power supply circuit to the main motor.
Check the items that follow:
•
The connection between the main motor (
P/J212
) and the drive PWB (
P/J405
) for
open circuit, short circuit or poor contact.
•
The drive gear for wear, damage or bearing blockage.
•
Load towards the main motor.
Install new components as necessary:
•
Main motor,
PL 40.10 Item 1
.
•
Drive PWB,
PL 1.10 Item 3
.
The fault may be intermittent. Check the connection between the main motor (
P/J212
pin 2)
and the drive PWB (
P/J405
pin 4) for open circuit, short circuit or poor contact.
Install new components as necessary:
•
Drive PWB,
PL 1.10 Item 3
.
•
ESS PWB,
PL 3.10 Item 6
.
042-330 Fuser Exhaust Fan Fail RAP
BSD-ON:
BSD 10.3 Fusing
042-330 Fuser exhaust fan fault.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Refer to the procedure that follows as necessary:
•
GP 6
How to Check a Motor.
Enter
dC330
code 042-050 to run the fuser exhaust fan. The fuser exhaust fan runs.
Y
N
Check the +24V power supply to the fuser exhaust fan. The power supply is good.
Y
N
Check the power supply circuit to the fuser exhaust fan.
Check the items that follow:
•
The connection between the fuser exhaust fan(
P/J210
) and the drive PWB (
P/
J413
) for open circuit, short circuit or poor contact.
•
Load towards the fuser exhaust fan.
Install new components as necessary:
•
Fuser exhaust fan,
PL 40.15 Item 4
.
•
Drive PWB,
PL 1.10 Item 3
.
The fault may be intermittent. Check the connection between the fuser exhaust fan (
P/J210
pin 2) and the drive PWB (
P/J413
pin 2) for open circuit, short circuit or poor contact.
Install new components as necessary:
•
Drive PWB,
PL 1.10 Item 3
.
•
ESS PWB,
PL 3.10 Item 6
.