![background image](http://html2.mh-extra.com/html/xerox/phaser-8860/phaser-8860_service-manual_3590364112.webp)
09/2007
3-20
Phaser 8860/8860MFP Service Manual
IQ26, IQ27
Initial Issue
Image Quality
IQ26 Vertical Lines Appear Wavy
This RAP addresses image quality problems associated with the Print Engine. Wavy or ill-
formed vertical lines typically result from excessive Drum oiling. An error in X-Axis or Y-Axis
motion could also cause this problem. Wavy vertical lines can appear as follows:
Figure 1 Example of Wavy Vertical Lines on Output
Initial Actions
1.
Check that supported media is being used.
2.
Check the Drum Maintenance Kit.
Procedure
IQ27 Oil Streaks on Print
This RAP addresses image quality problems associated with the Print Engine. Oil streaking
typically results from excessive Drum oiling. An problem with the Drum Maintenance Kit is the
likely cause. Oil streaks can appear as follows:
Figure 1 Example of Oil Streaks on Output
Initial Actions
1.
Check that supported media is being used.
2.
Check the Drum Maintenance Kit.
3.
Run the Remove Print Smears routine.
Procedure
Table 1 IQ26 Vertical Lines Appear Wavy
Step Questions and Actions
Yes
No
1
Check and clean the Drum Maintenance Kit
Wiper Blade.
Does the problem persist?
Replace the Drum
Maintenance Kit. If
the problem per-
sists, go to Step 2.
Complete.
2
Check X-Axis motion.
Verify that there is nothing interfering with X-
Axis motion.
Replace any defective parts found.
Does the problem persist?
Go to Step 3.
Complete.
3
Check Y-Axis motion.
Run the Service Diagnostics Y-Axis Encoder
test.
Does the problem persist?
Go to Step 4.
Complete.
4
Check the Drum maintenance Cam Roller
and Pivot Plate are functioning correctly.
Run the Service Diagnostics Drum Mainte-
nance tests.
Does the problem persist?
Replace any
defective parts
found.
Complete.
Table 1 IQ27 Oil Streaks on Print
Step Questions and Actions
Yes
No
1
Check and clean the Drum Maintenance Kit
Wiper Blade.
Does the problem persist?
Replace the Drum
Maintenance Kit. If
the problem per-
sists, go to Step 2.
Complete.
2
Check the Drum Maintenance Kit ground con-
nection.
Verify that the ground connection is secure
between the Drum Maintenance Shaft and
Drum Fan.
Does the problem persist?
Go to Step 3.
Complete.
3
Run the Remove Print Smears routine.
Does the problem persist?
Go to Step 4.
Complete.
4
Clean the Stripper Blade and Exit Guides.
Does the problem persist?
Go to Step 5.
Complete.
Summary of Contents for Phaser 8860
Page 1: ...705P01205 September 2007 Phaser 8860 8860MFP Service Documentation...
Page 4: ...09 2007 iv Phaser 8860 8860MFP Service Manual Initial Issue Introduction...
Page 28: ...09 2007 1 2 Phaser 8860 8860MFP Service Manual Initial Issue Service Call Procedures...
Page 34: ...09 2007 2 2 Phaser 8860 8860MFP Service Manual Initial Issue Error Messages and Codes...
Page 94: ...09 2007 3 2 Phaser 8860 8860MFP Service Manual Initial Issue Image Quality...
Page 126: ...09 2007 4 2 Phaser 8860 8860MFP Service Manual Initial Issue Repairs and Adjustments...
Page 208: ...09 2007 5 2 Phaser 8860 8860MFP Service Manual Initial Issue Parts List...
Page 222: ...09 2007 6 2 Phaser 8860 8860MFP Service Manual Initial Issue Diagnostics...
Page 274: ...09 2007 7 2 Phaser 8860 8860MFP Service Manual Initial Issue Wiring Data...
Page 294: ...09 2007 8 2 Phaser 8860 8860MFP Service Manual Initial Issue Theory of Operation...