105
CHAPTER 5 - START-UP
ACTION
LED DISPLAY
DESCRIPTION
LCD DISPLAY
Press the
key to enter the
programming mode
Use the
and
keys to set
the correct motor rated frequency
value
Press the
key to save the
programmed value and exit the
programming mode
Press the
key to go to the next
parameter
Press the
key to enter the
programming mode
Use the
and
keys to set
the correct motor rated rpm value
Press the
key to save the
programmed value and exit the
programming mode
Press the
key to go to the
next parameter
Enter the programming mode
Programmed Motor Rated
Frequency: 60 Hz
Exit the programming mode
Motor Rated rpm Range:
0 to 18000 rpm
Enter the programming mode
Programmed Motor Rated rpm:
1730 rpm
Exit the programming mode
Motor Rated hp Range:
1 to 1600.0 hp
1 to 1190.0 kW
Moto r Rated Freq
P403 = 60 Hz
Moto r Rated Freq
P403 = 60 Hz
Moto r Rated Freq
P403 = 60 Hz
Moto r Rated
rpm
P402 = 1730 rpm
Moto r Rated
rpm
P402 = 1730 rpm
Moto r Rated
rpm
P402 = 1730 rpm
Moto r Rated
rpm
P402 = 1730 rpm
Mo to r R ated
HP
P404 = 5.0 HP