158
CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
Figure 6.25
- Block diagram of the local / remote mode
REFERENCE
(P221)
(*)
LOCAL
REFERENCE
REMOTE
REFERENCE
LOCAL
COMMANDS
REMOTE
COMMANDS
LOCAL/REMOTE
Selection (P220)
REFERENCE
COMMANDS
COMMANDS
REFERENCE
FWD/REV
(P223)
JOG
(P225)
START/STOP
(P224)
LOCAL
REMOTE
REFERENCE
(P222)
(*)
FWD/REV
(P226)
JOG
(P228)
START/STOP
(P227)
(*)
For P221 = 11 (PLC) or P222 = 11 (PLC) the speed reference will be the total reference according to the figure 6.26.