CFW-09 -
QUICK PARAMETER REFERENCE
13
Parameters
Function
Adjustable Range
Factory
Unit
User's
Page
Setting
Setting
7 = Loads User Default 1
8 = Loads User Default 2
9 = Not Used
10 = Save User Default 1
11 = Save User Default 2
P205
Display Default Selection
0 = P005 (Motor Frequency) 2 = P002
-
149
1 = P003 (Motor Current)
2 = P002 (Motor Speed)
3 = P007 (Motor Voltage)
4 = P006 (Inverter Status)
5 = P009 (Motor Torque)
6 = P070 (Motor Speed and
Motor Current)
7 = P040 (PID Process
Variable)
P206
Auto-Reset Time
0 to 255
0
s
150
P207
Reference Engineering Unit 1
32 to 127 (ASCII)
114 = r
-
150
A, B, ... , Y, Z
0, 1, ... , 9
#, $, %, (, ), *, +, ...
P208
(2) (11)
Reference Scale Factor
1 to 18000
1800 (1500)
-
150
P209
(1)
Motor Phase Loss Detection
0 = Off
0 = Off
-
151
1 = On
P210
Decimal Point of the Speed Indication 0 to 3
0
-
151
P211
(1)
Zero Speed Disable
0 = Off
0 = Off
-
151
1 = On
P212
Condition to Leave Zero
0 = N* or N>P291
0 = N* or N>P291
-
152
Speed Disable
1 = N*>P291
P213
Time Delay for Zero Speed Disable
0 to 999
0
s
152
P214
(1) (9)
Line Phase Loss Detection
0 = Off
1 = On
-
152
1 = On
P215
(1)
Keypad Copy Function
0 = Off
0 = Off
-
152
1 = Inverter
Keypad
2 = Keypad
Inverter
P216
Reference Engineering Unit 2
32 to 127 (ASCII)
112 = p
-
154
A, B, ... , Y, Z
0, 1, ... , 9
#, $, %, (, ), *, +, ...
P217
Reference Engineering Unit 3
32 to 127 (ACSII)
109 = m
-
154
A, B, ... , Y, Z
0, 1, ... , 9
#, $, %, (, ), *, +, ...
P218
LCD Display Contrast
0 to 150
127
-
154
Adjustment
Local/Remote Definition
P220
(1)
Local/Remote Selection Source
0 = Always Local
2 = Keypad
-
154
1 = Always Remote
(Default Local)
2 = Keypad (Default Local)
3 = Keypad (Default Remote)