T214 main unit installation
Chapter 4. Installation.
37
4.6.6
Power supply connection
Basic power supply is 100÷240 VAC , 45÷65 Hz ; back up – 24VDC.
Cable to connect «110-220 VAC, 45-65 Hz» shall have wire with area not less than
3
х
0.75mm
2
with connectors like IEC 60320 C13 «Continental Europe».
Number of pin
Designation
Connector type
1
~220 V, N
2
~220 V, L
3 GND
IEC 60320 C14,
110÷240 VAC,
45÷65 Hz
1
2
3
1 +24
V
2 -24
V
3 GND
206036-2, AMP,
24 VDC
Cable to connect back up 24VDC shall have the area depending on the length but
not less than indicated in the table.
Cable length
Required area of the wire
0.0 -10.0 m
3
х
1.0 mm
2
10.0 -20.0 m
3
х
1.5 mm
2
20.0 -40.0 m
3
х
3.0 mm
2